Results from the August pump tests showed a drawdown in all wells drilled to the 795–800 ft. elevation range. PCBs at MW-4I peaked at 4000 ppb 5 minutes into the test, while there was no decrease in PCB content at ICS at the time of the test. Water flow at ICS decreased about 7 gpm at the start of the test, while PCBs at ICS decreased from 8.8 to 2.5 ppb 48 hours after the test. Two pump tests were conducted on LF-6 but only about 9 gallons pumped were from each test, and it was concluded that it was not a good location for a pumping well.
|
|
Warning! Eat no fish from Clear Creek, Pleasant Run, Salt or Richland Creeks.
|
|||
COPA For more info, e-mail info@copa.org. Copyright © 1990-2002 COPA, Inc. All rights reserved. See legal page for terms of use and disclaimers. All trademarks belong to their respective owners. |
|||